What is the difference between collect and sum?
SUM.
When processing an internal table in a block starting with LOOP and concluded by ENDLOOP , SUM calculates the control totals of all fields of type I , F and P (see also ABAP/4 number types ) and places them in the LOOP output area (header line of the internal table or an explicitly specified work area).
When you use SUM in a LOOP with an explicitly specified output area, this output area must be compatible with the line type of the internal table.When using LOOP to process a sorted extract (see SORT ), the control total of f at the end of the group appears in the field SUM(f) - - if f is type I , F or P .
COLLECT.
COLLECT is used to create unique or compressed datsets. The key fields are the default key fields of the internal table itab .
If you use only COLLECT to fill an internal table, COLLECT makes sure that the internal table does not contain two entries with the same default key fields.
If, besides its default key fields, the internal table contains number fields,the contents of these number fields are added together if the internal table already contains an entry with the same key fields.
If the default key of an internal table processed with COLLECT is blank, all the values are added up in the first table line.
If you specify wa INTO , the entry to be processed is taken from the explicitly specified work area wa . If not, it comes from the header line of the internal table itab .
After COLLECT , the system field SY-TABIX contains the index of the - existing or new - table entry with default key fields which match those of the entry to be processed.
COLLECT can create unique or compressed datasets and should be used precisely for this purpose. If uniqueness or compression are unimportant, or two values with identical default key field values could not possibly occur in your particular task, you should use APPEND instead. However, for a unique or compressed dataset which is also efficient, COLLECT is the statement to use.
If you process a table with COLLECT , you should also use COLLECT to fill it. Only by doing this can you guarantee that the internal table will actually be unique or compressed, as described above and COLLECT will run very efficiently.
If you use COLLECT with an explicitly specified work area, it must be compatible with the line type of the internal table.
SUM.
When processing an internal table in a block starting with LOOP and concluded by ENDLOOP , SUM calculates the control totals of all fields of type I , F and P (see also ABAP/4 number types ) and places them in the LOOP output area (header line of the internal table or an explicitly specified work area).
When you use SUM in a LOOP with an explicitly specified output area, this output area must be compatible with the line type of the internal table.When using LOOP to process a sorted extract (see SORT ), the control total of f at the end of the group appears in the field SUM(f) - - if f is type I , F or P .
COLLECT.
COLLECT is used to create unique or compressed datsets. The key fields are the default key fields of the internal table itab .
If you use only COLLECT to fill an internal table, COLLECT makes sure that the internal table does not contain two entries with the same default key fields.
If, besides its default key fields, the internal table contains number fields,the contents of these number fields are added together if the internal table already contains an entry with the same key fields.
If the default key of an internal table processed with COLLECT is blank, all the values are added up in the first table line.
If you specify wa INTO , the entry to be processed is taken from the explicitly specified work area wa . If not, it comes from the header line of the internal table itab .
After COLLECT , the system field SY-TABIX contains the index of the - existing or new - table entry with default key fields which match those of the entry to be processed.
COLLECT can create unique or compressed datasets and should be used precisely for this purpose. If uniqueness or compression are unimportant, or two values with identical default key field values could not possibly occur in your particular task, you should use APPEND instead. However, for a unique or compressed dataset which is also efficient, COLLECT is the statement to use.
If you process a table with COLLECT , you should also use COLLECT to fill it. Only by doing this can you guarantee that the internal table will actually be unique or compressed, as described above and COLLECT will run very efficiently.
If you use COLLECT with an explicitly specified work area, it must be compatible with the line type of the internal table.
How we format the data before before write statement in report ?
We can format the reports output by using the loop events like:
1.at first
2.at new
3.at last
etc check docu
We can format the reports output by using the loop events like:
1.at first
2.at new
3.at last
etc check docu
What is the difference between Table and Template?
table is a dynamic and template is a static
table is a dynamic and template is a static
When do we use End-of-selection?
End-of-selection event are mostly used when we are writing HR-ABAP code. In the HR-ABAP code, data is retrived in the Start-of-selection event and Printing on the list and all will be done in End-of-selection event.
End-of-selection event are mostly used when we are writing HR-ABAP code. In the HR-ABAP code, data is retrived in the Start-of-selection event and Printing on the list and all will be done in End-of-selection event.